SCPI Commands :

SOURce:GPRF:GENerator<Instance>:LIST:INCRement:ENABling:CATalog
SOURce:GPRF:GENerator<Instance>:LIST:INCRement:ENABling
class EnablingCls[source]

Enabling commands group definition. 2 total commands, 0 Subgroups, 2 group commands

get_catalog() List[str][source]
# SCPI: SOURce:GPRF:GENerator<Instance>:LIST:INCRement:ENABling:CATalog
value: List[str] = driver.source.listPy.increment.enabling.get_catalog()

Lists all initial trigger modes that can be set using method RsCmwGprfGen.Source.ListPy.Increment.Enabling.value.

return:

enabling_srcs: string Comma-separated list of strings. Each string represents a supported initial trigger mode.

get_value() str[source]
# SCPI: SOURce:GPRF:GENerator<Instance>:LIST:INCRement:ENABling
value: str = driver.source.listPy.increment.enabling.get_value()

For an internally incremented list, this command defines the initial trigger. Internally incremented list means ‘List Increment: GPRF Gen<i>: … Marker …’ or ‘List Increment: Dwell Time’, see method RsCmwGprfGen.Source.ListPy.Increment. value.

return:

enabling: string To generate a complete list of all supported triggers, see method RsCmwGprfGen.Source.ListPy.Increment.Enabling.catalog. ‘Immediate’: No initial trigger; list increment starts immediately. ‘Manual’: Waits until method RsCmwGprfGen.Source.ListPy.Slist.set is executed. ‘meas trigger’ (e.g. ‘GPRF Measi: Power’ or ‘GSM Measi: Multi Evaluation’) : Some measurement application provides the initial trigger.

set_value(enabling: str) None[source]
# SCPI: SOURce:GPRF:GENerator<Instance>:LIST:INCRement:ENABling
driver.source.listPy.increment.enabling.set_value(enabling = 'abc')

For an internally incremented list, this command defines the initial trigger. Internally incremented list means ‘List Increment: GPRF Gen<i>: … Marker …’ or ‘List Increment: Dwell Time’, see method RsCmwGprfGen.Source.ListPy.Increment. value.

param enabling:

string To generate a complete list of all supported triggers, see method RsCmwGprfGen.Source.ListPy.Increment.Enabling.catalog. ‘Immediate’: No initial trigger; list increment starts immediately. ‘Manual’: Waits until method RsCmwGprfGen.Source.ListPy.Slist.set is executed. ‘meas trigger’ (e.g. ‘GPRF Measi: Power’ or ‘GSM Measi: Multi Evaluation’) : Some measurement application provides the initial trigger.